Saturday, March 25, 2006

I have an old Pelton & Crane Autoclave. What do they make now?


Delta XL Sterilizer Features

  • Available in 8" or 10" chamber sizes.
  • One custom and four automatic pre- programmed sterilization settings allow you to select the appropriate cycle according to type of load.
  • Variable timed drying cycle saves time by giving operator the flexibility to set drying time according to load size.
  • Automatic chamber preheat maximizes productivity by shortening cycle times.
  • Filtered air drying ensures wet packs and pouches will dry without compromising the sterility of instruments by airborne contaminants.
  • Electronic temperature and time control systematically monitor sterilization conditions in chamber to ensure cycle completion.
  • Digital function display allows easy and accurate monitoring of sterilization cycle.
  • New, bright graphics ensure that display is easy to read.
  • Optional time/ temperature recorder for office documentation.
  • Designed and built to ASME specifications.
  • Six month replacement/ three year limited parts warranty.

Is there a big, fast, automatic steam sterilizer?


The Tuttnauer EZ-10 Fully Automatic Steam Autoclave
With the simplicity of one touch design all of your sterilization and
drying needs are fulfilled. The Tuttnauer fully automatic autoclaves fill, sterilize, exhaust and dries at the touch of a button. All EZ models feature a closed door active drying system to maintain sterility and ensure efficient drying of packs and pouches.
The EZ series is also available in a quick cycle model, the
Kwiklave (EZ10k) . This sterilizer offers all the proven, dependable
features of our fully automatic autoclaves with the added benefit of
reducing the total sterilization cycle time by 50%. Speed and reliability are accomplished without sacrificing load size. Kwiklave is the perfect choice for quick instrument turn-around or a high volume office.

FEATURES:
- New contemporary design with an easier to read bright blue display panel.
- Pre-loaded cycles for: unwrapped instruments; wrapped/packs;
liquid and additional drying cycle.
- All program parameters can be changed and stored.
- Automatic shut off at the end of both the sterilization and dry cycles.
- Audible and visual cycle interruption alert.
- Double safety locking device prevents door from opening while chamber is pressurized.
- Low water sensor prevents activation of sterilization cycle when there is insufficient water in the chamber or reservoir.
- Constant monitoring of temperature and pressure for sterilization.
- Power outage recovery system.
- Door design prevents steam from coming in contact with control panel.
- Optional printer.
PLUS:
-High Efficiency air pump.
-Decreased overall drying time.
-Closed door drying.
-Hepa filter 0.2μm air filter (replaceable)
-Circulates hot air after the sterilization cycle for fast drying.

Model....Volume....Chamber Dimensions....Overall Dimensions
EZ9............5gal...................9" x 18.5".................21.5" x 20" x 14.4"
EZ10..........6gal.................10" x 18.7".................21.5" x 20" x 14.4"
EZ10k........6gal.................10" x 18.7".................21.5" x 20" x 14.4"
3870EA....22gal................15.1" x 29.9"..............34.5" x 26" x 20.6"

STANDARDS:
Approved by major International Standards for autoclaves, i.e.
A.S.M.E., TUV, CE 01123, UL, etc.

Thursday, March 23, 2006

Is there a Really Big Autoclave Sterilizer for a large practice?



The Pelton & Crane Magna-Clave

The Pelton & Crane Magna~Clave sterilizer has been the dental industry's encore performer for over 30 years. With a proven track record and accomodating size, the Magna~Clave is ideal for the busy group practice, emergency clinic or small hospital. The Magna~Clave makes sterilization quick and easy with its state-of-the-art features and large chamber. You can feel confident of uncomprimising sterilization with Pelton & Crane autoclaves.

Features

  • Large size is ideal for the busy group practice, emergency clinic, or small hospital
  • ASME- type safety valve to limit maximum chamber pressure to 34 PSI
  • Capacity to sterilize up to 14 Hu- Friedy cassettes or equivalent
  • One medium shallow tray and one basket tray
  • Designed and manufactured to meet requirements of ASME Boiler and Pressure Vessel Codes

Is there a Really Big Autoclave for a large practice?


Left~click twice to enlarge image.

Monday, March 20, 2006

Does Midmark Ritter make a big 11 inch sterilizer?


Midmark M11 UltraClave® Automatic Sterilizer
It's the one with the door that opens Today, more than ever, you need reliable and easy to use products from a trusted partner who understands your sterilization needs. The Midmark M11 UltraClave® Automatic Sterilizer was specifically designed and engineered to meet those needs. The intuitive display and simple prompts help you easily select the cycle you need... whether it is for unwrapped items, pouches, packs or handpieces. Once the sterilization process is complete, the door conveniently opens automatically and quietly to dissipate the steam and provide fast and efficient drying time of your instruments.

Create peace of mind by making the healthcare market’s leading autoclave... the Midmark M11 UltraClave... your preferred office choice.

Pouch Rack
2 pouch racks

Vertical Cassette Rack
Holds four standard 8" x 11" cassettes.

Horizontal Cassette Rack
Holds four standard 8" x 11" cassettes.

Convenience at a glance.
The LCD display indicates cycle selected, cycle temperature and exposure time. When the cycle enters sterilization mode and dry mode, the remaining cycle time is displayed as well as temperature and pressure.

No more wet instruments.
Once the sterilization is complete, the door opens automatically and quietly to dissipate steam and dry your instruments. You’ll have dry, sterile instruments every time.

Safety features.
If the door is not closed completely or the reservoir water level is low, the LCD display will provide the appropriate message. In either case, sterilization can’t continue until you’ve attended to the unit.

Ease of draining & filling.
For ease of draining and filling, the Midmark M11’s reservoir fill port and drain tube is in the front of the unit, not on top or in back.

Optional printer accessory.
The Midmark M11 printer accessory provides a permanent record of cycles, times, temperatures and pressures during a cycle.

Self Program Controls
Programmable controls allow for creation of different cycle parameters for special sterilization needs. Programmable buttons allow you to change the following: Time (3 to 90 minutes), Temperature (230 to 275˚F), Dry Time (0 to 60 minutes), or Vent (slow or fast). The #1 and #2 buttons allow you to store the change if desired.

Pre-Programmed Controls
Four pre-programmed sterilization cycle controls: Unwrapped (132º C or 270º F for 3 minutes), Pouched (132º C or 270º F for 5 minutes), Packs (121º C or 250º F for 30 minutes), Handpiece (unwrapped and pouched) (132˚ C or 270˚ F for 6 minutes).

LCD Display
Indicates cycle selected, temperature and exposure time. During the cycle, the display shows messages describing status. When the cycle enters sterilization mode and dry mode, remaining time is displayed as well as temperature and pressure.

Cycle Start Button
(Initiates selected cycle)

Manual Stop Button
(Terminates selected cycle or function)

Midmark M11D AutoClave® Automatic Sterilizer

The Midmark M11D AutoClave® Automatic Sterilizer offers easy, effective sterilization but without the convenience of a door that opens automatically. One button starts the cycle... but at the end of the automatic sterilization process, you need to manually open the door within 30 minutes of completion to activate the dry cycle. This extra step is the only physical difference between the Midmark M11D and its automatic counterpart.

Which sterilizer is best for a busy Lasik Eye Surgery Center?


The Statim-5000 Cassette Steam Autoclave
Larger than the 2000, the Statim 5000 has an additional sterilization cycle and a roomier cassette designed to process bulkier instruments and greater loads. It's a reliable cassette sterilizer that's compact enough to fit in patient treatment areas and fast enough to sterilize expensive dental handpieces and instruments between procedures - it can complete an unwrapped sterilization cycle in just nine minutes and a wrapped cycle in just 17.5 minutes. The Statim 5000 is also fully automatic. Simply select one of four sterilization programs and with a single touch of the keypad, begin the cycle. An advanced microprocessor controls all functions and maintains optimal sterilization conditions, from start to finish. SciCan's Statim cassette sterilizers have a biological effectiveness that has been proven in tests for hollow and solid instruments at many internationally recognized institutes in Canada, the United States and Europe. * Cycle times do not include drying.
Specifications:
Unit Size :
L 555mm x W 415mm x H 190mm
L 21.75" x W 16.25" x H 7.5"
Cassette Internal Dimensions:
L 380mm x W 180mm x H 75mm
L 15" x W 7" x H 3"
Reservoir Capacity : 4.0 litres (distilled water)
Weight without water : 33 kg / 72 lbs
Power Consumption : 110-120 V, 60 Hz, 1300 W
Optional Printer : Type: Thermal printer
Print: 20 characters/ line
Speed: 1 line/ sec.
Capacity: 80 cycles/ roll

Statim FAQs

Q: What type of water do I use with Statim?

A: Always use steam-distilled water in the Statim Cassette Autoclave. Other water sources will damage the unit and void the warranty.
Q: How do I test the quality of distilled water?

A: If purchasing distilled water, SciCan recommends using a water conductivity tester (SciCan part no. 01-103139S) to check for impurities.
Q: How do I prepare instruments for use with Statim?
A: Thoroughly wash, rinse, and dry all instruments before inserting into the Statim.
Q: How often do I clean the interior and exterior of the cassette?

A: Keeping the Statim cassette clean is good clinical practice. The interior surface of the cassette should be cleaned at least once a week with a mild, chlorine-free dishwashing soap. To promote quick drying, we recommend spraying the cassette lid and tray with Stat-Dri after each cleaning. For detailed instructions concerning cassette cleaning and the use of Stat-Dri, see the Statim Operator's Manual.

Q: What do I do if steam or a puddle of water is detected during or after a cycle?
A: If steam or a puddle of water is detected during or after a cycle, check the cassette seal. This problem may be corrected by doing the following:

a) Replacing the seal if it is older than six months or has been used for more than 500 cycles.
b) Cleaning the outside edge of the tray.
c) Checking the seal for damage and/or misalignment.

Q: What if I receive an error code?

A: If the LCD displays a NOT STERILE message, note the error code and consult the Troubleshooting section of your Operator's Manual.

Q: Do I need to ensure that the Statim is level before operating?

A: Yes. Before operating your Statim autoclave, make sure it rests on a flat and level surface. If you are uncertain, the level indicator on the front panel and leveler feet underneath the unit will help you correct any problems. (Align the bubble in the level indicator to the right front quadrant of the target.)

Q: What do I do if my Statim has not been run for several days?

A: If you do not operate your Statim autoclave for several days, run two wrapped instrument cycles. Conduct a thorough cassette cleaning and rinse, and apply Stat-Dri to the cassette tray and lid after cleaning.

Q: How should I drain the reservoir?

A: To empty the reservoir, use the drain tube. If your Statim does not have a drain tube, a hand pump will suffice. Except when filling or emptying the reservoir, keep the reservoir cap securely fastened at all times.
Q: What should I do if the Statim is on, but not in use?

A: If your Statim is powered ON but not in use, pull the cassette 1-2cm out of the unit. This will make the unit inactive until the cassette is reinserted and will prolong the life of your unit.
Q: How do I recognize whether my filter(s) needs replacement?

A: Monitor the white air filter and the bacteria-retentive filter at the back of the unit. A dirty filter will cause poor drying. If the filter has turned gray, it is in need of replacement (see the maintenance section of the Operator's Manual).

Q: How do I transport my Statim?

A: Whenever you need to transport your Statim, make sure you empty the water reservoir and screw-in the feet. Repack your Statim in the original packing materials to reduce any damage, and don't forget to include the country kit, cassette and waste water bottle.

Sunday, March 19, 2006

Are there any accessories available for the Statim-5000 Cassette Steam Stearilizer?










Wednesday, March 15, 2006

Is there a Choice of Laboratory Style Vertical Sterilizers or Autoclaves?




Vertical Hospital & Laboratory
Steam Sterilizers & Autoclaves
HV series

The Most Advanced Autoclaves
with Unique Features

Model
Effective capacity
Chamber size(㎜)
Outer dimensions
(W×H×D㎜)

Max.Steril.temp

Process mode
Net weight
HV-25
25liter
240φ×550D
9.4" x 21.6"
480×950×460

126℃

4-modes
41kg
HV-50
50liter
300φ×710D
11.8" x 28"
510×1040×530

135℃

4-modes
57kg

Model
Effective capacity
Chamber size(㎜)
Outer dimensions
(W×H×D㎜)

Max.Steril.temp

Process mode
Net weight
HV-85
85liter
420φ×615D
16.5" x 24.2"
660×1000×650

135℃

4-modes
71kg
HV-110
110liter
420φ×795D
16.5" x 31.3"
660×1180×650

135℃

4-modes
81kg

Electromechanical lock system
By only using a one-touch lever,
you can easily and safely Open or
Lock the lid












*Electromechanical lock system
*Dual-sensing interlock mechanism
*Double-sensing system for air evacuation
*Programmable auto start
*Process status display
*Process mode for agar

Retrofittable accessories
(Any combination possible)

A : Forced cooling unit
F : Floating sensor
P : Digital printer
W : Automatic water supply
Z : All combined (A+F+P+W)

Tuesday, March 14, 2006

Are there any Baskets, Pails or Dressing Drums for Vertical Sterilizers?









Three different types of stainless steel containers of different heights (large, medium and small) are available for handling different loads. Stacking shorter containers can increase load capacity (two medium-sized and three small-sized containers can fit in a given chamber). A mesh wire basket is suitable for most loads, including glassware and media. A pail is used for media and Petri dishes with liquid in them as well as to contain potential spillage from waste bags. A drum has a hinged lid with a handle. Depending on the load, it serves as a closed (but not watertight) trash container or as a carrying and storage case. The side and bottom of the drum are perforated for better steam penetration. Sliding panels cover these perforations prior to and after sterilization. Two round stainless steel tube racks, either with capacity for sixty 20-mm or ninety 13-mm tubes per rack, are also available. You can stack the tube racks by putting them inside the accessory containers.
Hirayama Baskets, Pails & Dressing Drums
Basket for HV-25, Stainless Steel 8.3 inches Diameter x 17.5 inches High
Basket for HV-25, Stainless Steel 8.3 inches Diameter x 10.2 inches High
Pail for HV-25, Stainless Steel 8.3 inches Diameter x 9.8 inches High
Drum HV-25, Stainless Steel 8.3 inches Diameter x 6.8 inches High
Basket for 50L, Stainless Steel 10.7 inches Diameter x 22.0 inches High
Basket for 50L, Stainless Steel 10.7 inches Diameter x 11.8 inches High
Basket for 50L, Stainless Steel 10.7 inches Diameter x 8.7 inches High
Basket with 5.0 inch Solid Bottom for 50L, Stainless Steel 10.5 inches Diameter x 24.0 inches High
Pail for 50L, Stainless Steel 10.7 inches Diameter x 10.7 inches High
Pail for 50L, Stainless Steel 10.7 inches Diameter x 8.3 inches High
Drum with Hinged Lid for 50L, Stainless Steel 10.7 inches Diameter x 7.1 inches High
Basket for HV-85/110, Stainless Steel 15.3 inches Diameter x 23.3 inches High
Basket for HV-85, Stainless Steel 15.3 inches Diameter x 11.5 inches High
Basket for HV-85, Stainless Steel 15.3 inches Diameter x 7.5 inches High
Pail for HV-85, Stainless Steel 15.3 inches Diameter x 11.0 inches High
Basket for HV-110, Stainless Steel 15.3 inches Diameter x 15.0 inches High
Basket for HV-110, Stainless Steel 15.3 inches Diameter x 9.3 inches High
Pail for HV-110, Stainless Steel 15.3 inches Diameter x 15.0 inches High

Friday, March 10, 2006

Is there a Portable, Vertical Sterilizer Autoclave for Laboratories & Hospitals?

Tomy ES-215 and ES-315 Autoclaves
with Delayed Start Timer and Warming Cycle are completely self-contained, compact, and portable. They roll right to your workbench to give you fast, effective sterilization of media, glassware, instruments, and disposables - on the spot and on your schedule. The ES Series Autoclaves also feature three cycles of operation and Graphic Process Display.


The ES-215 and ES-315 Autoclaves provide convenient processing of your laboratory sterilization and media preparation needs. These functional autoclaves offer three cycles of operation ranging from basic sterilization cycles to automatic warming cycles.
The eight hour warming cycle featured in the Tomy ES Series Autoclaves may be used directly following a sterilization cycle or independently to melt and keep sterile media ready for use.
To increase your convenience, these cycles may be programmed up to 99 hours in advance using the Delayed Start Timer. This feature enables you to have sterile media on hand and ready for use when you need it.
Tomy Autoclaves also spare you the initial installation costs associated with the plumbing and hard wiring of conventional autoclaves because they are portable. Just plug in the power cord, add water, and let the self-contained steam generator and venting system do the rest.
Tomy's vertical loading autoclaves accommodate a wide range of items. Small items like petrie dishes and test tubes are easily accommodated in the stacking baskets while large items like a fermenter or a 25 liter carboy may are also available for sterilizing liquids. To ensure your safety and complete sterilization, Tomy Autoclaves are equipped with independent temperature and pressure monitoring system.
Programmable Control Panel

Operation is very easy. Just select the cycle and set the temperature and time. The rest is automatic. A graphic display and audible alarm let you know the process and completion of the operation.
Specifications
Model ES-215
Chamber Capacity 22 liters
Operating Temperature 105 to 123 degrees Celsius
Temperature control Microprocessor Control
Temperature Increments 1 degree
Temperature Display Type Digital
Pressure Display Range 0 to 2.0 Kgf/sq. cm
Pressure Display Type Analog
Maximum Operating Pressure 1.5Kgf/sq. cm
Sterilization Heat Source Stainless steel electric heater, 1.5 Kw
Time Display 1 to 240 minutes, and continuous (Sterilization Cycle)
1 to 8 hours (Warming Cycle)
Dimensions 400 mm W x 460 mm D x 920 mm H
15.75 in H x 18.11 in D x 36.22 in H

Height of Worksurface 705 mm// 27.76 inches

Chamber Diameter 248 mm// 9.76 inches

Chamber Height 450 mm// 17.72 inches

Net Weight 50 Kg// 110.23 Pounds

Power 110/120V,50/60Hz, 15 amps
220/230/240V,50/60Hz, 7 amps

Model
ES-315
Chamber Capacity
53 liters
Operating Temperature
105 to 132 degrees Celsius
Temperature control Microprocessor Control
Temperature Increments 1 degree
Temperature Display Type Digital
Pressure Display Range
0 to 3.5 Kgf/sq. cm
Pressure Display Type Analog
Maximum Operating Pressure
2.2 Kgf/sq. cm
Sterilization Heat Source
Stainless steel electric heater, 2.0 Kw
Time Display 1 to 240 minutes, and continuous (Sterilization Cycle)
1 to 8 hours (Warming Cycle)
Dimensions
490 mm W x 560 mm D x 1,090 mm H
19.29 in W x 22.05 in D x 42.91 in H
Height of Worksurface
875 mm// 34.45 inches
Chamber Diameter
325 mm// 12.8 inches
Chamber Height
635 mm// 25 inches
Net Weight
80 Kg// 176.37 Pounds
Power
110/120V,50/60Hz, 20 amps
220/230/240V,50/60Hz, 10 amps

Sunday, March 05, 2006

Is there a Pre-Vac Post-Vac Table Top Sterilizer with a Water Filtration System?


PV Dry™ Steam with Pre/Post-Vacuum
• Auto-fill water technology
• Eliminate risk of instrument recontamination
• Faster drying times with an average start-to-dry cycle of 40 minutes
• Guarantee that all pouches and instruments will come out dry

Product Description
• Vacuum-closed-door sterile drying of goods for speed and sterile integrity.
• Patented non-recirculation system means less chamber cleaning time.
• Patented automatic door-closing system eliminates hard-to-close doors.
• Pulsed pre-vacuum for maximum steam penetration.
• Five preset cycles allow simple operation of wrapped, unwrapped, packs,
liquid and special cycles.
• Large chamber, yet small foot-print saves valuable counter space.
• Easy connection to printer or data port for validation or record keeping.
• Easy to read LCD display lets you view all parameters.
• Custom programs can be created in lab mode for unique applications.
• Meets highest national performance expectations, AAMI - ST-55
performance standard, as well as pressure vessel safety standards.
• Type B* sterilizer is defined by European Normative EN13060 (2004).
• Custom cast long-life heating element minimizes service and repair cost.
• Built-in diagnostic system is accessible from front panel for quick service.
• Removes calcium, magnesium, and other ionic impurities that can harm your steam sterilizer
• Automatically fills and automatically drains sterilizer when used with Harvey PV Dry Steam Sterilizer

Specifications
Description: PV Dry Sterilizer w/Harvey DI Kit
Accessories Included: Rack, 1 large tray, 1 small tray
Amps: 7.3
Chamber Capacity: .70 cubic feet (20 L); .52 cubic (15 L) usable space
Chamber Dimensions: 10" diameter, 15.5" depth (25.4 x 39.4 cm)
Fixed Cycle Parameters:
Liquids: 15 min @ 121°C
Unwrapped: 3 min @ 135°C
Wrapped: 5 min @ 135°C
Packs: 30 min @ 121°C
Special: 5 min @ 134°C
Heater Wattage 1800
Overall Dimensions: WxHxD
19" x 15.5" x 23" (48.3 x 39.4 x 58.4 cm)
Product Line Harvey
Shipping Weight LK 155 (70.3)
Volts 240
Harvey DI+ Water Pretreatment System

• Removes calcium, magnesium, and other ionic impurities that can harm your steam sterilizer
• Automatically fills and automatically drains sterilizer when used with Harvey PV Dry Steam Sterilizer

Product Description
• Easy to set up—quick fitting connectors connect directly to your faucet—requires no power.
• Compact—mounts to the wall for easy installation.
• Fast—produces up to 4 liters of pure water per minute.
• Reliable—Barnstead has been in the pure water market for over 125 years—trust the water expert.
• Low Cost—23 cents per gallon cost based on average tap water (171 ppm).
• No need to store containers of distilled water.
• Connect a Harvey DI+ system to your water source and pure water is available at your request.
• The new Harvey DI+ system incorporates nuclear grade resin enclosed in virgin polypropylene canister to purify tap water.
Operation
• Pura-lite notifies user when it is time to install new cartridge.
• Simple Maintenance—quarter-turn quick release canister.
• The Harvey DI+ water system provides pre-treated water for your steam sterilizer at the push of a button.